Siare MRI Compatible Anaesthesia Machine Morpheus LT
- Product Code: P-003
Features :
Automatic ventilator.
Has both O2 and N2O flowmeter.
Fully automatic air ventilation and gas delivery system.
Selektateck or cone type options for vaporizer device.More Information
Brand Saikang
Country of Origin Italy
Description
Specifications :
Ventilation modalities : MANUAL, VC-VAC, PCV-APCV
Breathing rate : From 5 to 90 bpm (step 1 bpm)
I:E Ratio : 1:4 ÷ 4:1
Inspiratory time : From 0.2 to 5 sec.
Tidal Volume : From 50 to 1500 ml
Minute Volume : From 1 ÷ 30 liters
PEEP OFF : 3 ÷ 30 cmH2O
Inspiratory Flow : From 1 ÷ 80 L/min.
Oximeter Minimum resolution : 1% / Automatic calibration procedure
High pressure limit : From 10 to 80 cmH2O
Bronchomanometer Electronic : from -10 ÷ 80 cmH2O
Flow trigger : From OFF, 1 to 15 L/min (step 1 L/min)
Pressure trigger : From OFF, -1 to -9 cmH2O under the PEEP level
Safety : Electronic and mechanical limit of airways pressure / Self-diagnosis system
Flow sensor : Pressure relief single patient sensor
Alarms : Fan Failure, Air Failure, High / Low Airways Pressure, Low O2 concentration, O2 cell into operation or not present, Apnoea, Expired Tidal Volume, Power Failure, Low Battery.
Measured parameters : PAW, FiO2 , VM, Tinsp, RATE, Vte
Seller Bio-X
- Brand: SonoScape
- Viewed: 1266
- Availability: 37
₹1,858,500
Features :
Automatic ventilator.
Has both O2 and N2O flowmeter.
Fully automatic air ventilation and gas delivery system.
Selektateck or cone type options for vaporizer device.More Information
Brand Saikang
Country of Origin Italy
Description
Specifications :
Ventilation modalities : MANUAL, VC-VAC, PCV-APCV
Breathing rate : From 5 to 90 bpm (step 1 bpm)
I:E Ratio : 1:4 ÷ 4:1
Inspiratory time : From 0.2 to 5 sec.
Tidal Volume : From 50 to 1500 ml
Minute Volume : From 1 ÷ 30 liters
PEEP OFF : 3 ÷ 30 cmH2O
Inspiratory Flow : From 1 ÷ 80 L/min.
Oximeter Minimum resolution : 1% / Automatic calibration procedure
High pressure limit : From 10 to 80 cmH2O
Bronchomanometer Electronic : from -10 ÷ 80 cmH2O
Flow trigger : From OFF, 1 to 15 L/min (step 1 L/min)
Pressure trigger : From OFF, -1 to -9 cmH2O under the PEEP level
Safety : Electronic and mechanical limit of airways pressure / Self-diagnosis system
Flow sensor : Pressure relief single patient sensor
Alarms : Fan Failure, Air Failure, High / Low Airways Pressure, Low O2 concentration, O2 cell into operation or not present, Apnoea, Expired Tidal Volume, Power Failure, Low Battery.
Measured parameters : PAW, FiO2 , VM, Tinsp, RATE, Vte
Seller Bio-X