Byond Infusion Pump BYS-820
- Product Code: BYS-820
Description
Byond Infusion Pump BYS–820 is a bubble detector and pressure sensor that can precisely detect air bubbles. It features KVO and Bolus functions, a unique voice alarm system and an accurate injection rate to make the injection process safer and more reliable.
Features:
HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting, etc., which gain patents;
Compatible with any brands of infusion sets after correct calibration;
Preset solution volume to greatly reduce the workload of nurses;
Work mode: ml/h and drop/min can switch freely;
Three levels of occlusion: high, middle and low;
Purge function;
KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1-5ml/h(1ml/h step);
Power Source: AC100—240V, 50/60Hz; Internal Battery;
Automatically record the settings of last infusion;
OEM is available.
Specifications:
Rate
1ml/h ~ 1,200ml/h
Flow Rate Accuracy
Within +/- 5% (after correct calibration)
Mechanical precision
Within +/- 2%
Purge Rate
100ml/h ~ 1,000ml/h (100 ml/h step)
Infusion Volume
1ml ~ 9999ml
Total Infusion Volume
0.1ml ~ 9999.9ml
KVO rate
1ml/h ~ 5 ml/h (1ml/h step)
Occlusion
High: 800mmHg +/- 200mmHg (106.7kPa +/- 26.7kPa)
Medium: 500mmHg +/- 100mmHg (66.7kPa +/-13.3kPa)
Low: 300mmHg +/-100mmHg (40.7kPa +/-13.3kPa )
Unique audible and visible alarm
Human voice alarm for end of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out etc.
Power Source
AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity1,600mAh, 4 hours internal battery backup
Bubble detector
Ultrasonic wave detector; detection sensitivity 25mu/L
Fuse
F1AL/250V, 2 pc inside
Power Consumption
18VA
Operating Condition
Ambient temperature: +5℃ ~ +40℃;
Relative humidity: 20 ~ 90%
Atmospheric pressure: 86.0kpa ~ 106.0kpa
Transport & Storage Condition
Ambient temperature:-30℃ ~ +55℃
Relative humidity: ≤95%
Equipment Classification
Class II, internal power supply, Type CF
IP Classification
IPX4
Dimension
140mm (L);157mm(W);220mm(H)
Weight
1.8kg (net weight)
- Brand: Byond
- Viewed: 1007
- Availability: 10
₹42,480
Description
Byond Infusion Pump BYS–820 is a bubble detector and pressure sensor that can precisely detect air bubbles. It features KVO and Bolus functions, a unique voice alarm system and an accurate injection rate to make the injection process safer and more reliable.
Features:
HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting, etc., which gain patents;
Compatible with any brands of infusion sets after correct calibration;
Preset solution volume to greatly reduce the workload of nurses;
Work mode: ml/h and drop/min can switch freely;
Three levels of occlusion: high, middle and low;
Purge function;
KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1-5ml/h(1ml/h step);
Power Source: AC100—240V, 50/60Hz; Internal Battery;
Automatically record the settings of last infusion;
OEM is available.
Specifications:
Rate
1ml/h ~ 1,200ml/h
Flow Rate Accuracy
Within +/- 5% (after correct calibration)
Mechanical precision
Within +/- 2%
Purge Rate
100ml/h ~ 1,000ml/h (100 ml/h step)
Infusion Volume
1ml ~ 9999ml
Total Infusion Volume
0.1ml ~ 9999.9ml
KVO rate
1ml/h ~ 5 ml/h (1ml/h step)
Occlusion
High: 800mmHg +/- 200mmHg (106.7kPa +/- 26.7kPa)
Medium: 500mmHg +/- 100mmHg (66.7kPa +/-13.3kPa)
Low: 300mmHg +/-100mmHg (40.7kPa +/-13.3kPa )
Unique audible and visible alarm
Human voice alarm for end of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out etc.
Power Source
AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity1,600mAh, 4 hours internal battery backup
Bubble detector
Ultrasonic wave detector; detection sensitivity 25mu/L
Fuse
F1AL/250V, 2 pc inside
Power Consumption
18VA
Operating Condition
Ambient temperature: +5℃ ~ +40℃;
Relative humidity: 20 ~ 90%
Atmospheric pressure: 86.0kpa ~ 106.0kpa
Transport & Storage Condition
Ambient temperature:-30℃ ~ +55℃
Relative humidity: ≤95%
Equipment Classification
Class II, internal power supply, Type CF
IP Classification
IPX4
Dimension
140mm (L);157mm(W);220mm(H)
Weight
1.8kg (net weight)