Detachable embolization coil
- Product Code: Q-038
GALAXY G3™ Microcoil
GALAXY G3™ Microcoils have a complex shape and the unique proprietary random loop design which does not follow a predefined shape. The random loops pursue a unique path each time they are deployed.
GALAXY G3™ Microcoils conform to the true aneurysm shape and seeks open space to fill concentrically, from the periphery to the core.
The GALAXY G3™ Microcoil System is compatible with microcatheters with inner lumen diameters ranging from 0.0165 to 0.021 in (0.419 to 0.533 mm).
Optimal balance of softness and support
GALAXY G3™ Microcoil has a superior volumetric filling versus 10-System coils.1 The microcoil has a primary outer diameter of 0.012”.
Random Complex Stretch Resistant Coil
Random complex coils are shown to have better conformability and provide excellent framework for concentric filling, dense packing, and lower retreatment rates vs. other existing helical and complex coils.2
Random Shape, Predictable Results
Shape integrity with a variety of increasing coil softness. Tight Distal Loop (TDL) Technology: the first loop of all GALAXY G3™ Microcoils 4mm in diameter and larger is one third smaller than the labeled coil diameter and is designed to facilitate the anchoring of the coil in the aneurysm.
- Brand: Depuy Synthes
- Viewed: 2709
- Availability: 21
₹0
Tags: detachable coil medical intervention embolization interventional radiology precision medical device
GALAXY G3™ Microcoil
GALAXY G3™ Microcoils have a complex shape and the unique proprietary random loop design which does not follow a predefined shape. The random loops pursue a unique path each time they are deployed.
GALAXY G3™ Microcoils conform to the true aneurysm shape and seeks open space to fill concentrically, from the periphery to the core.
The GALAXY G3™ Microcoil System is compatible with microcatheters with inner lumen diameters ranging from 0.0165 to 0.021 in (0.419 to 0.533 mm).
Optimal balance of softness and support
GALAXY G3™ Microcoil has a superior volumetric filling versus 10-System coils.1 The microcoil has a primary outer diameter of 0.012”.
Random Complex Stretch Resistant Coil
Random complex coils are shown to have better conformability and provide excellent framework for concentric filling, dense packing, and lower retreatment rates vs. other existing helical and complex coils.2
Random Shape, Predictable Results
Shape integrity with a variety of increasing coil softness. Tight Distal Loop (TDL) Technology: the first loop of all GALAXY G3™ Microcoils 4mm in diameter and larger is one third smaller than the labeled coil diameter and is designed to facilitate the anchoring of the coil in the aneurysm.





