GB DRACA 200 FULLY AUTOMATED BIO-CHEMISTRY ANALYZER
- Product Code: TTD007
PRODUCT DESCRIPTION
Fully Automated Biochemistry Analyzer
FEATURES
Constant 200 test/hour with double reagent
80 reagent position
Automatic liquid level sensing, anti-collision protection
Integrated full closed optical system, multi-wavelength simultaneous detection
New amorphous optical plastic reaction cups perfect transmittance
Maintenance-free semiconductor solid-state refrigeration
Friendly surface and easy to operation
The multifunction precision sampling probe
Excellent mixer design
High precision ceramic syringe
TECHNICAL SPECIFICATION
MACHINE TYPE Random Access with dedicated DRACA system packs
TEST SPEED 200 Test/Hour
TEST PRINCIPLE Colorimetric Method, Turbidimeter
TEST METHOD 1 Point End,2 Point End, Fixed Time, Kinetics
CALIBRATION TYPE Linear & Nonlinear
REAGENT TRAY 80 Reagent positions (40 for R1 & 40 for R2), Non-stop cooling system with Peltier pad inside,24 Hours 2'c-14'c
REAGENT VOLUME 20-300μl, Step by 1μl
REAGENT NEEDLE
Liquid Surface Detection, Timely Tracking for Liquid volume, collision Avoidance.
OPERATING SYSTEM
Windows XP,7,8,10
DATA PROCESSING
Automatic calibration test combination
Effective time management of reagents
Serum index
Whole process detection
Linear expansion of enzyme
Blank deduction
Dirty cuvette memory
Cross infection prevention
Patient information memory and association input
Automatic report audit
Data fuzzy query
Report statistics and printing
Reference range grading
Alarm information classification
User operation privilege classification management
REPORT PRINTING
6 Format, optional, support custom pattern
INTERFACE
TCP/IP network interface
SAMPLE TRAY
40 Sample position
SAMPLE TUBE
Micro cup & Test tube & Blood collection tube can be used (12-13)mm*(25-100)mm
SAMPLE PROBE
2-30μL, Step BY 0.1μL
SAMPLE PROBE
Liquid surface detection
Timely tracking for liquid volume
collision avoidance
SAMPLE BARCODE
OPTIONAL
MIXER-PADDLE
Type mixing, effective reducing of carryover
LIGHT SOURCE
Halogen lamp
WAVELENGTH
340.405.45.505.546.578.630.700 (nm) 4 more options
ABSORBANCE RANGE
0-4.0 Abs
RESOLUTION
0.0001Abs-4.0 Abs
POWER SUPPLY
AC 110/220V±10%,50/60 Hz,650W
WATER CONSUMPTION
8L/Hours (Maximum)
DIMENSION
870mm*690mm*740mm(L*W*H)
WEIGHT
80 Kg
REACTION TRAVY
44 Reaction cuvettes, new amorphous optical plastics reaction cups,perfect transmittance
REACTION VOLUME
50μL-30μL
REACTION TIME
10 MINUTES
TEMPERATURE
Peltier pad incubation system, reaction temperature (37'C ± 0.1 'C)
- Brand: Genuine Biosystem
- Viewed: 1335
- Availability: 46
₹1,681,500
PRODUCT DESCRIPTION
Fully Automated Biochemistry Analyzer
FEATURES
Constant 200 test/hour with double reagent
80 reagent position
Automatic liquid level sensing, anti-collision protection
Integrated full closed optical system, multi-wavelength simultaneous detection
New amorphous optical plastic reaction cups perfect transmittance
Maintenance-free semiconductor solid-state refrigeration
Friendly surface and easy to operation
The multifunction precision sampling probe
Excellent mixer design
High precision ceramic syringe
TECHNICAL SPECIFICATION
MACHINE TYPE Random Access with dedicated DRACA system packs
TEST SPEED 200 Test/Hour
TEST PRINCIPLE Colorimetric Method, Turbidimeter
TEST METHOD 1 Point End,2 Point End, Fixed Time, Kinetics
CALIBRATION TYPE Linear & Nonlinear
REAGENT TRAY 80 Reagent positions (40 for R1 & 40 for R2), Non-stop cooling system with Peltier pad inside,24 Hours 2'c-14'c
REAGENT VOLUME 20-300μl, Step by 1μl
REAGENT NEEDLE
Liquid Surface Detection, Timely Tracking for Liquid volume, collision Avoidance.
OPERATING SYSTEM
Windows XP,7,8,10
DATA PROCESSING
Automatic calibration test combination
Effective time management of reagents
Serum index
Whole process detection
Linear expansion of enzyme
Blank deduction
Dirty cuvette memory
Cross infection prevention
Patient information memory and association input
Automatic report audit
Data fuzzy query
Report statistics and printing
Reference range grading
Alarm information classification
User operation privilege classification management
REPORT PRINTING
6 Format, optional, support custom pattern
INTERFACE
TCP/IP network interface
SAMPLE TRAY
40 Sample position
SAMPLE TUBE
Micro cup & Test tube & Blood collection tube can be used (12-13)mm*(25-100)mm
SAMPLE PROBE
2-30μL, Step BY 0.1μL
SAMPLE PROBE
Liquid surface detection
Timely tracking for liquid volume
collision avoidance
SAMPLE BARCODE
OPTIONAL
MIXER-PADDLE
Type mixing, effective reducing of carryover
LIGHT SOURCE
Halogen lamp
WAVELENGTH
340.405.45.505.546.578.630.700 (nm) 4 more options
ABSORBANCE RANGE
0-4.0 Abs
RESOLUTION
0.0001Abs-4.0 Abs
POWER SUPPLY
AC 110/220V±10%,50/60 Hz,650W
WATER CONSUMPTION
8L/Hours (Maximum)
DIMENSION
870mm*690mm*740mm(L*W*H)
WEIGHT
80 Kg
REACTION TRAVY
44 Reaction cuvettes, new amorphous optical plastics reaction cups,perfect transmittance
REACTION VOLUME
50μL-30μL
REACTION TIME
10 MINUTES
TEMPERATURE
Peltier pad incubation system, reaction temperature (37'C ± 0.1 'C)